MSS60 Error: 2724, P0132: Difference between revisions
Jump to navigation
Jump to search
Created page with "{| |'''Information saved in''' |DME |- |'''Fault code''' |2724 - P0132 |- |'''Fault text''' |Oxygen sensor, signal before cat., bank 1 |- |'''Fault description''' |O2 Sensor C..." |
No edit summary |
||
| Line 1: | Line 1: | ||
{| | ====2724 - P0132==== | ||
{| class = "diyTable ecuFault" | |||
|'''Information saved in''' | |'''Information saved in''' | ||
|DME | |DME | ||
Latest revision as of 03:17, 12 January 2015
2724 - P0132
| Information saved in | DME |
| Fault code | 2724 - P0132 |
| Fault text | Oxygen sensor, signal before cat., bank 1 |
| Fault description | O2 Sensor Circuit High Voltage (Bank 1 Sensor 1) |
| Condition for fault identification | Test condition: lavk_atic42_pin_diag_b1 BIT1 or BIT3 or BIT5 or BIT7 set |
| Terminal condition: none | |
| Voltage condition: none | |
| Condition for fault memory entry | 3000 ms |
| Action in service | 1. Check plug and wiring harness on pre-cat oxygen sensor LSVK B1, |
| 2. If OK replace oxygen sensor | |
| Fault effect and breakdown warning | MIL on after engine runs 2x |
| Driver information | Warning light: MIL |
| Service instruction | None |