MSS60 Error: 2724, P0132
Jump to navigation
Jump to search
2724 - P0132
| Information saved in | DME |
| Fault code | 2724 - P0132 |
| Fault text | Oxygen sensor, signal before cat., bank 1 |
| Fault description | O2 Sensor Circuit High Voltage (Bank 1 Sensor 1) |
| Condition for fault identification | Test condition: lavk_atic42_pin_diag_b1 BIT1 or BIT3 or BIT5 or BIT7 set |
| Terminal condition: none | |
| Voltage condition: none | |
| Condition for fault memory entry | 3000 ms |
| Action in service | 1. Check plug and wiring harness on pre-cat oxygen sensor LSVK B1, |
| 2. If OK replace oxygen sensor | |
| Fault effect and breakdown warning | MIL on after engine runs 2x |
| Driver information | Warning light: MIL |
| Service instruction | None |