MSS60 Error: 2B29, P16B1, P16B7, P16B8, P16C1
Jump to navigation
Jump to search
2B29 - P16B1
| Information saved in | DME |
| Fault code | 2B29 - P16B1 |
| Fault text | Moment manager monitoring |
| Fault description | Control Module Self-Test, Idle Air Control System Integrated Component Plausibility |
| Condition for fault identification | Test condition: I-component greater than 70 Nm (K_MD_SK_LLR_MAX) |
| Terminal condition: Terminal 15 | |
| Voltage condition: None | |
| Condition for fault memory entry | 10 ms |
| Action in service | 1. Clear fault memory |
| 2. Update DME | |
| 3. Replace DME | |
| Fault effect and breakdown warning | CC message |
| Engine speed limited | |
| Reduced power | |
| MIL after engine runs 2x | |
| Driver information | Warning light: MIL, EML, CC message, backup program |
| Service instruction | None |
2B29 - P16B7
| Information saved in | DME |
| Fault code | 2B29 - P16B7 |
| Fault text | Moment manager monitoring |
| Fault description | Control Module Self-Test, Clutch Torque Monitoring Maximum Value Plausibility |
| Condition for fault identification | Test condition: Specified torques greater than 620 Nm (K_MD_SK_IND_MAX) |
| Terminal condition: Terminal 15 | |
| Voltage condition: None | |
| Condition for fault memory entry | 10 ms |
| Action in service | 1. Clear fault memory |
| 2. Update DME | |
| 3. Replace DME | |
| Fault effect and breakdown warning | CC message |
| Engine speed limited | |
| Reduced power | |
| MIL after engine runs 2x | |
| Driver information | Warning light: MIL, EML, CC message, backup program |
| Service instruction | None |
2B29 - P16B8
| Information saved in | DME |
| Fault code | 2B29 - P16B8 |
| Fault text | Moment manager monitoring |
| Fault description | Control Module Self-Test, Clutch Torque Monitoring Minimum Value Plausibility |
| Condition for fault identification | Test condition: Minimum torque greater than 70 Nm (K_MD_SK_MAX_MDMIN) |
| Terminal condition: Terminal 15 | |
| Voltage condition: None | |
| Condition for fault memory entry | 10 ms |
| Action in service | 1. Clear fault memory |
| 2. Update DME | |
| 3. Replace DME | |
| Fault effect and breakdown warning | CC message |
| Engine speed limited | |
| Reduced power | |
| MIL after engine runs 2x | |
| Driver information | Warning light: MIL, EML, CC message, backup program |
| Service instruction | None |
2B29 - P16C1
| Information saved in | DME |
| Fault code | 2B29 - P16C1 |
| Fault text | Moment manager monitoring |
| Fault description | Control Module Self-Test, Torque Monitoring Current Indicated Value Plausibility |
| Condition for fault identification | Test condition: Difference too large |
| Terminal condition: Terminal 15 | |
| Voltage condition: None | |
| Condition for fault memory entry | 10 ms |
| Action in service | 1. Check load monitoring |
| 2. Clear fault memory | |
| 3. Update DME | |
| 4. Replace DME | |
| Fault effect and breakdown warning | CC message |
| Engine speed limited | |
| Reduced power | |
| MIL after engine runs 2x | |
| Driver information | Warning light: MIL, EML, CC message, backup program |
| Service instruction | None |