MSS60 Error: 2742, P0135

From Wiki-DIY
Jump to navigation Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.


2742 - P0135

Information saved in DME
Fault code 2742 - P0135
Fault text Oxygen sensor heater resistance diagnosis before cat. converter, bank 1
Fault description O2 Sensor Heater Circuit (Bank 1 Sensor 1)
Condition for fault identification Test condition: The upper or lower threshold of the resistance values has been violated, above/below 6.0 ohms (K_LSHVK_DIAG_RU) 14.5 ohms (K_LSHVK_DIAG_RO)
Terminal condition: Engine running
Voltage condition: Battery voltage > 9V (k_ed_ubmin)
Condition for fault memory entry min. K_LSHVK_DIAG_ANZ_MESS (100) valid calculations of heater resistance - roughly.1.5 sec.
Action in service 1. DME software release must be more recent than 07-06-510, fix incorporated since 07-09-521
2. Check plug, wiring harness on pre-cat oxygen sensor LSVK B1,
3. If OK, replace oxygen sensor
Fault effect and breakdown warning MIL lamp on after engine runs 2x /Small influence on drivability
Driver information Warning light: MIL
Service instruction None
MIL after engine runs 2x