Information saved in DME
Fault code 27E3 - P2526
Fault text Vacuum sensor, brake booster, plausibility
Fault description Vacuum Reservoir Pressure Sensor Circuit Range/Performance
Condition for fault identification Test condition: Sensor value deviates substantially from model value, with sensor value > Model value ensuring that ELUP activation threshold remains valid
. Terminal condition: Engine running
. Voltage condition: none
Condition for fault memory entry 1 min
Action in service 1. Check vacuum line,
. 2. Check 1-way check valves,
. 3. Check brake booster
Fault effect and breakdown warning MIL on after engine runs 2x
Driver information Warning light: MIL