MSS60 Error: 27B8, P0692
27B8 - P0692
| Information saved in | DME |
| Fault code | 27B8 - P0692 |
| Fault text | Electric fan, activation |
| Fault description | Fan 1 Control Circuit High |
| Condition for fault identification | Test condition: ATIC39 diagnosis message |
| . | Terminal condition: TERM87 |
| . | Voltage condition: Battery voltage > 9.8V (k_diag_tr_ub_min) |
| Condition for fault memory entry | 1000 ms |
| Action in service | 1. Check plug and wire on ELUE |
| . | 2. Check signal wire in wiring harness on DME |
| . | 3. Replace ELUE |
| Fault effect and breakdown warning | Fan has failed |
| . | Constant rise in engine temperature leading to CC message |
| Driver information | Warning light: none |
| Service instruction | none |