The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.
274B - P2629
| Information saved in
|
DME
|
| Fault code
|
274B - P2629
|
| Fault text
|
Oxygen sensor pump current calibration fault before cat. converter, bank 2
|
| Fault description
|
O2 Sensor Pumping Current Trim Circuit/Open (Bank 2 Sensor 1)
|
| Condition for fault identification
|
Test condition: Oxygen sensor is available, oxygen sensor voltage > 4951 mV (K_LAVK_OBD_SA_DIAG_OL)
|
| .
|
Terminal condition: Engine running - overrun condition
|
| .
|
Voltage condition: none
|
| Condition for fault memory entry
|
after a defined SA phase the lag period K_LAVK_OBD_SA_T (2.5 sec) must be completed
|
| Action in service
|
1. Check plug and wiring harness on pre-cat oxygen sensor LSVK B2 (especially trim circuit wire IA),
|
| .
|
2. If OK, replace oxygen sensor
|
| Fault effect and breakdown warning
|
MIL lamp on after engine runs 2x /Small influence on drivability
|
| Driver information
|
Warning light: MIL
|
| Service instruction
|