Information saved in
|
DME
|
Fault code
|
27B0 - P0491
|
Fault text
|
Secondary air system flow rate, bank 1
|
Fault description
|
Secondary Air Injection System Insufficient Flow (Bank 1)
|
Condition for fault identification
|
Test condition: sls_obdh_mdf_max_intg_norm (after roughly 30s)<K_SLS_OBDH_MDF_MIN_DEF and
|
.
|
sls_obdh_lam_asv_intg_norm < k_SLS_OBDH_MDF_2_MAG or
|
.
|
sls_obdh_lam_asv_intg_norm < k_SLS_OBDH_ASV_LI_OPE and K_SLS_OBDH_MDF_MIN_DEF>K_SLS_OBDH_MDF_MAX_DEF
|
.
|
Terminal condition: Engine running
|
.
|
Voltage condition: Battery voltage > 10.8 V (k_sls_obd_ub_min)
|
Condition for fault memory entry
|
30000 ms
|
Action in service
|
1. Disconnect secondary air line
|
.
|
2. Carry out test routine
|
.
|
3. If flow is too high, replace the ASV
|
.
|
4. Otherwise check Line 1 for obstructions and replace as indicated
|
Fault effect and breakdown warning
|
MIL is on after 2x engine cold start
|
Driver information
|
Warning light: MIL
|
Service instruction
|
None
|