Information saved in
|
DME
|
Fault code
|
2743 - P0155
|
Fault text
|
Oxygen sensor heater resistance diagnosis before cat. converter, bank 2
|
Fault description
|
O2 Sensor Heater Circuit (Bank 2 Sensor 1)
|
Condition for fault identification
|
Test condition: The upper or lower threshold of the resistance values has been violated, above/below 6.0 ohms (K_LSHVK_DIAG_RU) 14.5 ohms (K_LSHVK_DIAG_RO)
|
|
Terminal condition: Engine running
|
|
Voltage condition: Battery voltage > 9V (k_ed_ubmin)
|
Condition for fault memory entry
|
min. K_LSHVK_DIAG_ANZ_MESS (100) valid calculations of heater resistance - roughly.1.5 sec.
|
Action in service
|
1. DME software release must be more recent than 07-06-510, fix incorporated since 07-09-521
|
|
2. Check plug, wiring harness on pre-cat oxygen sensor LSVK B2,
|
|
3. If OK, replace oxygen sensor
|
Fault effect and breakdown warning
|
MIL lamp on after engine runs 2x /Small influence on drivability
|
Driver information
|
Warning light: MIL
|
Service instruction
|
None
|