MSS60 Error: 27B8, P0692: Difference between revisions
Jump to navigation
Jump to search
Created page with "{| | | |- |'''Information saved in''' |DME |- |'''Fault code''' |27B8 - P0692 |- |'''Fault text''' |Electric fan, activation |- |'''Fault description''' |Fan 1 Control Circuit..." |
No edit summary |
||
| Line 1: | Line 1: | ||
__FORCETOC__ | |||
| | |||
==== '''27B8 - P0692''' ==== | |||
{| class = "diyTable ecuFault" | |||
|- | |- | ||
|'''Information saved in''' | |'''Information saved in''' | ||
Revision as of 20:28, 3 February 2015
27B8 - P0692
| Information saved in | DME |
| Fault code | 27B8 - P0692 |
| Fault text | Electric fan, activation |
| Fault description | Fan 1 Control Circuit High |
| Condition for fault identification | Test condition: ATIC39 diagnosis message |
| . | Terminal condition: TERM87 |
| . | Voltage condition: Battery voltage > 9.8V (k_diag_tr_ub_min) |
| Condition for fault memory entry | 1000 ms |
| Action in service | 1. Check plug and wire on ELUE |
| . | 2. Check signal wire in wiring harness on DME |
| . | 3. Replace ELUE |
| Fault effect and breakdown warning | Fan has failed |
| . | Constant rise in engine temperature leading to CC message |
| Driver information | Warning light: none |
| Service instruction | none |