274B - P2629
Information saved in | DME |
Fault code | 274B - P2629 |
Fault text | Oxygen sensor pump current calibration fault before cat. converter, bank 2 |
Fault description | O2 Sensor Pumping Current Trim Circuit/Open (Bank 2 Sensor 1) |
Condition for fault identification | Test condition: Oxygen sensor is available, oxygen sensor voltage > 4951 mV (K_LAVK_OBD_SA_DIAG_OL) |
. | Terminal condition: Engine running - overrun condition |
. | Voltage condition: none |
Condition for fault memory entry | after a defined SA phase the lag period K_LAVK_OBD_SA_T (2.5 sec) must be completed |
Action in service | 1. Check plug and wiring harness on pre-cat oxygen sensor LSVK B2 (especially trim circuit wire IA), |
. | 2. If OK, replace oxygen sensor |
Fault effect and breakdown warning | MIL lamp on after engine runs 2x /Small influence on drivability |
Driver information | Warning light: MIL |
Service instruction | None |