MSS60 Error: 27E4, P1209: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
| Line 20: | Line 20: | ||
|Test condition: Constant violations of activation threshold or vacuum gradient is too low during activation | |Test condition: Constant violations of activation threshold or vacuum gradient is too low during activation | ||
|- | |- | ||
| | | | ||
|Terminal condition: TERM87 | |Terminal condition: TERM87 | ||
|- | |- | ||
| | | | ||
|Voltage condition: none | |Voltage condition: none | ||
|- | |- | ||
| Line 32: | Line 32: | ||
|1. Check ELUP fuse, | |1. Check ELUP fuse, | ||
|- | |- | ||
| | | | ||
|2. Check wires, | |2. Check wires, | ||
|- | |- | ||
| | | | ||
|3. Replace ELUP | |3. Replace ELUP | ||
|- | |- | ||
| Line 41: | Line 41: | ||
|CC message | |CC message | ||
|- | |- | ||
| | | | ||
|Engine speed limited | |Engine speed limited | ||
|- | |- | ||
| | | | ||
|Reduced power | |Reduced power | ||
|- | |- | ||
| | | | ||
|MIL after engine runs 2x | |MIL after engine runs 2x | ||
|- | |- | ||
Latest revision as of 20:40, 3 February 2015
27E4 - P1209
| Information saved in | DME |
| Fault code | 27E4 - P1209 |
| Fault text | Vacuum sensor, brake booster, plausibility |
| Fault description | Brake Booster Pump Shutoff Valve Plausibility |
| Condition for fault identification | Test condition: Constant violations of activation threshold or vacuum gradient is too low during activation |
| Terminal condition: TERM87 | |
| Voltage condition: none | |
| Condition for fault memory entry | 5000 ms |
| Action in service | 1. Check ELUP fuse, |
| 2. Check wires, | |
| 3. Replace ELUP | |
| Fault effect and breakdown warning | CC message |
| Engine speed limited | |
| Reduced power | |
| MIL after engine runs 2x | |
| Driver information | Warning light: MIL, EML, CC message, backup program |
| Service instruction | None |