MSS60 Error: 27E4, P1209: Difference between revisions
Jump to navigation
Jump to search
Created page with "{| | | |- |'''Information saved in''' |DME |- |'''Fault code''' |27E4 - P1209 |- |'''Fault text''' |Vacuum sensor, brake booster, plausibility |- |'''Fault description''' |Bra..." |
No edit summary |
||
| Line 1: | Line 1: | ||
__FORCETOC__ | |||
| | |||
==== '''27E4 - P1209''' ==== | |||
{| class = "diyTable ecuFault" | |||
|- | |- | ||
|'''Information saved in''' | |'''Information saved in''' | ||
Revision as of 20:40, 3 February 2015
27E4 - P1209
| Information saved in | DME |
| Fault code | 27E4 - P1209 |
| Fault text | Vacuum sensor, brake booster, plausibility |
| Fault description | Brake Booster Pump Shutoff Valve Plausibility |
| Condition for fault identification | Test condition: Constant violations of activation threshold or vacuum gradient is too low during activation |
| . | Terminal condition: TERM87 |
| . | Voltage condition: none |
| Condition for fault memory entry | 5000 ms |
| Action in service | 1. Check ELUP fuse, |
| . | 2. Check wires, |
| . | 3. Replace ELUP |
| Fault effect and breakdown warning | CC message |
| . | Engine speed limited |
| . | Reduced power |
| . | MIL after engine runs 2x |
| Driver information | Warning light: MIL, EML, CC message, backup program |
| Service instruction | None |