MSS60 Error: 27B2, P1412: Difference between revisions

From Wiki-DIY
Jump to navigation Jump to search
Created page with "{| | | |- |'''Information saved in''' |DME |- |'''Fault code''' |27B0 - P0491 |- |'''Fault text''' |Secondary air system flow rate, bank 1 |- |'''Fault description''' |Seconda..."
 
Blanked the page
Line 1: Line 1:
{|
 
|
|
|-
|'''Information saved in'''
|DME
|-
|'''Fault code'''
|27B0 - P0491
|-
|'''Fault text'''
|Secondary air system flow rate, bank 1
|-
|'''Fault description'''
|Secondary Air Injection System Insufficient Flow (Bank 1)
|-
|'''Condition for fault identification'''
|Test condition: sls_obdh_mdf_max_intg_norm (after roughly 30s)<K_SLS_OBDH_MDF_MIN_DEF and
|-
|'''.'''
|sls_obdh_lam_asv_intg_norm < k_SLS_OBDH_MDF_2_MAG or
|-
|'''.'''
|sls_obdh_lam_asv_intg_norm < k_SLS_OBDH_ASV_LI_OPE and K_SLS_OBDH_MDF_MIN_DEF>K_SLS_OBDH_MDF_MAX_DEF
|-
|'''.'''
|Terminal condition: Engine running
|-
|'''.'''
|Voltage condition: Battery voltage > 10.8 V (k_sls_obd_ub_min)
|-
|'''Condition for fault memory entry'''
|30000 ms
|-
|'''Action in service'''
|1. Disconnect secondary air line
|-
|'''.'''
|2. Carry out test routine
|-
|'''.'''
|3. If flow is too high, replace the ASV
|-
|'''.'''
|4. Otherwise check Line 1 for obstructions and replace as indicated
|-
|'''Fault effect and breakdown warning'''
|MIL is on after 2x engine cold start
|-
|'''Driver information'''
|Warning light: MIL
|-
|'''Service instruction'''
|None
|}

Revision as of 20:26, 3 February 2015