MSS60 Error: 2787, P3006: Difference between revisions
Jump to navigation
Jump to search
Created page with "{| | | |- |'''Information saved in''' |DME |- |'''Fault code''' |2787 - P3006 |- |'''Fault text''' |Fuel pressure, setpoint/actual-value comparison, controlled operation |- |'..." |
No edit summary |
||
| Line 1: | Line 1: | ||
__FORCETOC__ | |||
| | ====2787 - P3006==== | ||
{| class = "diyTable ecuFault" | |||
|- | |- | ||
|'''Information saved in''' | |'''Information saved in''' | ||
Latest revision as of 06:27, 11 March 2015
2787 - P3006
| Information saved in | DME |
| Fault code | 2787 - P3006 |
| Fault text | Fuel pressure, setpoint/actual-value comparison, controlled operation |
| Fault description | Fuel Rail Pressure Pressure-Rate-Controlled, Pressure Too High |
| Condition for fault identification | Test condition: Deviation between actual/specified pressure < -15 % (K_PKS_OBD_LL_MIN) |
| Terminal condition: Engine running | |
| Voltage condition: Battery voltage > 10.9V (k_pks_obd_ub_min) | |
| Condition for fault memory entry | 10000 ms |
| Action in service | 1. Carry out test routine |
| 2. Check plug and wiring harness at fuel-pressure sensor, replace sensor as indicated | |
| 3. Check plug and wiring harness at the fuel pump | |
| 4. Check fuel filter and pump, replace as indicated | |
| Fault effect and breakdown warning | CC message |
| Engine speed limited | |
| Reduced power | |
| MIL after engine runs 2x | |
| Driver information | Warning light: MIL, EML, CC message, backup program |
| Service instruction | None |