MSS60 Error: 27B2, P1412: Difference between revisions
Jump to navigation
Jump to search
Blanked the page |
No edit summary |
||
(2 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
__FORCETOC__ | |||
==== '''27B2 - P1412''' ==== | |||
{| class = "diyTable ecuFault" | |||
|- | |||
|'''Information saved in''' | |||
|DME | |||
|- | |||
|'''Fault code''' | |||
|27B2 - P1412 | |||
|- | |||
|'''Fault text''' | |||
|Secondary air system flow rate, main branch | |||
|- | |||
|'''Fault description''' | |||
|Secondary Air Pump/Secondary Air Valve Large Leak | |||
|- | |||
|'''Condition for fault identification''' | |||
|Test condition: sls_obdh_mdf_max_intg_norm (after roughly 30s) < K_SLS_OBDH_MDF_MIN_DEF and | |||
|- | |||
| | |||
|sls_obdh_lam_asv_intg_norm < k_SLS_OBDH_MDF_1_MAG and > k_SLS_OBDH_MDF_2_MAG or | |||
|- | |||
| | |||
|Terminal condition: Engine running | |||
|- | |||
| | |||
|Voltage condition: Battery voltage > 10.8 V (k_sls_obd_ub_min) | |||
|- | |||
|'''Condition for fault memory entry''' | |||
|30000 ms | |||
|- | |||
|'''Action in service''' | |||
|1. Check main harness for leaks and replace secondary air line as indicated | |||
|- | |||
|'''Fault effect and breakdown warning''' | |||
|MIL is on after 2x engine cold start | |||
|- | |||
|'''Driver information''' | |||
|Warning light: MIL | |||
|- | |||
|'''Service instruction''' | |||
|None | |||
|} |
Latest revision as of 20:27, 3 February 2015
27B2 - P1412
Information saved in | DME |
Fault code | 27B2 - P1412 |
Fault text | Secondary air system flow rate, main branch |
Fault description | Secondary Air Pump/Secondary Air Valve Large Leak |
Condition for fault identification | Test condition: sls_obdh_mdf_max_intg_norm (after roughly 30s) < K_SLS_OBDH_MDF_MIN_DEF and |
sls_obdh_lam_asv_intg_norm < k_SLS_OBDH_MDF_1_MAG and > k_SLS_OBDH_MDF_2_MAG or | |
Terminal condition: Engine running | |
Voltage condition: Battery voltage > 10.8 V (k_sls_obd_ub_min) | |
Condition for fault memory entry | 30000 ms |
Action in service | 1. Check main harness for leaks and replace secondary air line as indicated |
Fault effect and breakdown warning | MIL is on after 2x engine cold start |
Driver information | Warning light: MIL |
Service instruction | None |