Latest revision as of 20:51, 12 January 2015
278A - P0430
| Information saved in | DME |
| Fault code | 278A - P0430 |
| Fault text | Catalytic-converter conversion, bank 2 |
| Fault description | Catalyst System Efficiency Below Threshold (Bank 2) |
| Condition for fault identification | Test condition: Diagnosis value above threshold K_KAT_OBD_WERT_MAX |
| Terminal condition: Engine running - Condition idle or part-load | |
| Voltage condition: none | |
| Condition for fault memory entry | none |
| Action in service | 1. Check exhaust system for leaks |
| 2. No faults related to oxygen sensor or fuel system or VANOS should be present | |
| 3. Conduct oxygen sensor test routines, even if no oxygen sensor fault is present. | |
| 4. Replace catalytic conveter near engine | |
| Fault effect and breakdown warning | MIL on after engine runs 2x |
| Driver information | Warning light: MIL |
| Service instruction | None |