MSS60 Error: CDB6, UNK01: Difference between revisions
Jump to navigation
Jump to search
Created page with "{| | | |- |'''Information saved in''' |DME |- |'''Fault code''' |CDB6 |- |'''Fault text''' |Diagnosis monitors the required torque. |- |'''Fault description''' |Malfunction mo..." |
No edit summary |
||
| Line 1: | Line 1: | ||
__FORCETOC__ | |||
| | |||
==== '''CDB6 - UNK01''' ==== | |||
{| class = "diyTable ecuFault" | |||
|- | |- | ||
|'''Information saved in''' | |'''Information saved in''' | ||
Latest revision as of 21:25, 3 February 2015
CDB6 - UNK01
| Information saved in | DME |
| Fault code | CDB6 |
| Fault text | Diagnosis monitors the required torque. |
| Fault description | Malfunction monitoring conditions The fault is detected if the torque is higher than the required torque. |
| Condition for fault identification | Test condition: |
| Temperature condition - None | |
| Time condition - None | |
| Other preconditions - None | |
| Terminal status - Terminal 15 | |
| Voltage precondition: Vehicle voltage between 9V and 16V | |
| Condition for fault memory entry | The fault is entered immediately. |
| Action in service | Carry out bus system analysis |
| Fault effect and breakdown warning | None |
| Driver information | None |
| Service instruction | None |