MSS60 Error: 27B2, P1412: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
| Line 1: | Line 1: | ||
__FORCETOC__ | |||
| | |||
==== '''27B2 - P1412''' ==== | |||
{| class = "diyTable ecuFault" | |||
|- | |- | ||
|'''Information saved in''' | |'''Information saved in''' | ||
Revision as of 20:27, 3 February 2015
27B2 - P1412
| Information saved in | DME |
| Fault code | 27B2 - P1412 |
| Fault text | Secondary air system flow rate, main branch |
| Fault description | Secondary Air Pump/Secondary Air Valve Large Leak |
| Condition for fault identification | Test condition: sls_obdh_mdf_max_intg_norm (after roughly 30s) < K_SLS_OBDH_MDF_MIN_DEF and |
| . | sls_obdh_lam_asv_intg_norm < k_SLS_OBDH_MDF_1_MAG and > k_SLS_OBDH_MDF_2_MAG or |
| . | Terminal condition: Engine running |
| . | Voltage condition: Battery voltage > 10.8 V (k_sls_obd_ub_min) |
| Condition for fault memory entry | 30000 ms |
| Action in service | 1. Check main harness for leaks and replace secondary air line as indicated |
| Fault effect and breakdown warning | MIL is on after 2x engine cold start |
| Driver information | Warning light: MIL |
| Service instruction | None |