Created page with "{| | | |- |'''Information saved in''' |DME |- |'''Fault code''' |273E - P0030 |- |'''Fault text''' |Oxygen sensor final stage diagnosis heater before cat. converter, bank 1 |-..." |
(No difference)
|
Revision as of 05:19, 12 January 2015
| Information saved in | DME |
| Fault code | 273E - P0030 |
| Fault text | Oxygen sensor final stage diagnosis heater before cat. converter, bank 1 |
| Fault description | HO2S Heater Control Circuit (Bank 1 Sensor 1) |
| Condition for fault identification | Test condition: Driver info includes OPENLOAD |
| Terminal condition: none | |
| Voltage condition: none | |
| Condition for fault memory entry | 5000 ms |
| Action in service | 1. Check plug and wiring harness on pre-cat oxygen sensor LSVK B1, |
| 2. If OK replace oxygen sensor | |
| Fault effect and breakdown warning | MIL on after engine runs 2x |
| Driver information | Warning light: MIL |
| Service instruction | None |