MSS60 Error: 271B, P0015: Difference between revisions
Jump to navigation
Jump to search
Created page with "{| | | |- |'''Information saved in''' |DME |- |'''Fault code''' |271B - P0015 |- |'''Fault text''' |VANOS control, exhaust bank 1 |- |'''Fault description''' |'B' Camshaft Pos..." |
(No difference)
|
Revision as of 07:25, 11 January 2015
| Information saved in | DME |
| Fault code | 271B - P0015 |
| Fault text | VANOS control, exhaust bank 1 |
| Fault description | 'B' Camshaft Position - Timing Over-Retarded (Bank 1) |
| Condition for fault identification | Test condition: Filtered control deviation > 8.0°Crankshaft (K_VAN_XD_FILT_ED) |
| Terminal condition: Terminal 15 | |
| Voltage condition: Battery voltage > 9V (k_ed_ubmin) | |
| Condition for fault memory entry | 1 |
| Action in service | 1. Clear fault memory, VANOS system test |
| 2. Check valves, check adjuster | |
| Fault effect and breakdown warning | Error display in instrument / power reduction / engine speed governed to 7000 rpm / MIL on after engine runs 2x |
| Driver information | Warning light: MIL, EML, CC message, backup program |
| Service instruction | None |